As of June 12, 2018 our Privacy Policy has been updated. For individuals in the European Union, CIL uses cookies on this website. Please review the new privacy statement to see how. By continuing to use this website you agree to us using cookies in accordance with our privacy statement. Click here for the new privacy statement..OK

Corporate Overview

The Standard – June 2021

Dioxin/Furan Mixtures for Food/Feed and GC-MS/MS Analysis

Dioxins and furans have been considered one of the most toxic environmental pollutant classes for many decades. As has been evidenced from numerous accidental contamination events, they have also been one of the costliest environmental pollutants as well. Monitoring for these dangerous chemicals has been mandated for decades, and traditionally done by use of high-resolution gas chromatography with mass spectrometry (HRGC-MS). But in recent years the use of GC/MS-MS has developed as a viable option for testing, especially in food and feed methods where it is now approved for confirmatory testing in the EU food/feed directives. But are you using the proper standards to do this type of analysis?

It is well known that the major route of human exposure to dioxins and furans is through food consumption, and it is here that a major focus has occurred to actively reduce and potentially eliminate these chemicals from our food sources. In 2002 the European Union took legislative action and introduced strict guidance for maximum allowable limits for dioxins and furans in food and animal feed. While HRGC-MS was the basis for all testing at that time, in 2014 it was determined that methods using newer GC-MS-MS based systems could be used to confirm dioxin and furan testing results. This acceptance has opened a much broader approach to analytical testing in food and feed.
 
There are two points of interest regarding analytical standards used in dioxin and furan testing for food and feed: 
1. Most laboratories are still using US EPA methods developed in the 1990s
The older EPA methods were developed when isotopically labeled standards were still quite rare, and not all 17 analytes have 13C- surrogate standards. Over the years CIL has developed many new “non-2,3,7,8 containing” dioxin and furan standards which can be used as injection/recovery standards, allowing the use of all 17 13C-labeled “2,3,7,8-containing” congeners as surrogate/extraction standards. 
 
2. Use of triple-quadrupole GC/MS-MS systems require some low-level calibrant to set minimum detection levels (MDL)
Due to the lack of signal:noise calculations in GC/MS-MS systems, an accurate and very low level calibration level must be used to establish MDLs.  
 
CIL developed the Food/Feed/QQQ Calibration Series and labeled and unlabeled spiking mixtures specifically to resolve these issues. We believe these are the most appropriate standards for analysis of dioxins and furans in food and feed, and utilizing GC/MS-MS because: 

All 17 “2,3,7,8-containing” isotopically labeled (13C) extraction standards are included

“Non 2,3,7,8-containing” isotopically labeled (13C) injection standards are included

Ten (10) calibration series levels with native concentration ranges from 10 fg/µL to 200 pg/µL TCDD equivalence are useful for low level analysis for food/feed and other matrices (blood, etc.), and higher levels for contaminated products or other higher level environmental samples

Extra-low-level calibration levels (10, 20 fg/µL) may be used with GC-MS/MS triple-quadrupole instruments to establish minimum detection levels

Calibration series includes relative native concentrations 1:2:5 for Tetra/Penta:Hexa/Hepta:Octa homolog levels

Spiking solutions at standard concentration and 10x concentration to meet the needs of labs with smaller or larger demands

Use of 13C6-1,2,3,4-tetrachlorodibenzo-p-dioxin cleanup standard rather than 37Cl4-TCDD for extracts requiring extra processing. 

Calibration Series

EDF-5554 – Full calibration levels 1-8 (50-200,000 fg TCDD) 

EDF-5554-L – Low-end calibration levels 1-7 (50-50,000 fg TCDD)

EDF-5554-H – High-end calibration levels 2-8 (100-200,000 fg TCDD)

EDF-5554-CS0.2 – Low calibration level (10 fg TCDD)

EDF-5554-CS0.4 – Low calibration level (20 fg TCDD)

Catalog No. Description Amount
Dioxin & Furan Food/Feed/QQQ Calibration Series (CS1-CS8) 8 × 0.25 mL in nonane
EDF-5554-H Dioxin & Furan Food/Feed/QQQ Calibration Series (CS2-CS8) 7 × 0.25 mL in nonane
Dioxin & Furan Food/Feed/QQQ Calibration Series (CS1-CS7) 7 × 0.25 mL in nonane
Dioxin & Furan Food/Feed/QQQ Calibration Standard (CS0.2) 0.25 mL in nonane
Dioxin & Furan Food/Feed/QQQ Calibration Standard (CS0.4) 0.25 mL in nonane

 

Extraction Spike

Catalog No. Description Amount
EDF-5555 Dioxin & Furan Food/Feed/QQQ Extraction Standard 1.2 mL in nonane
EDF-5555-10X Dioxin & Furan Food/Feed/QQQ Extraction Standard (10X Stock) 1.2 mL in nonane

 

Injection Spike

Catalog No. Description Amount
EDF-5556 Dioxin & Furan Food/Feed/QQQ Injection Standard 1.2 mL in nonane
EDF-5556-10X Dioxin & Furan Food/Feed/QQQ Injection Standard (10X Stock) 1.2 mL in nonane

 

Cleanup Spike

Catalog No. Description Amount
EDF-5574 Dioxin & Furan Food/Feed/QQQ Cleanup Standard 1.2 mL in nonane
EDF-5574-10X Dioxin & Furan Food/Feed/QQQ Cleanup Standard (10X Stock) 1.2 mL in nonane

 

Native Spike

Catalog No. Description Amount
EDF-5557 Dioxin & Furan Food/Feed/QQQ PAR Standard 1.2 mL in nonane

 