As of June 12, 2018 our Privacy Policy has been updated. For individuals in the European Union, CIL uses cookies on this website. Please review the new privacy statement to see how. By continuing to use this website you agree to us using cookies in accordance with our privacy statement. Click here for the new privacy statement..OK

Corporate Overview

IsoTopics™ – November 2016

Quality Management in Clinical Application of Mass Spectrometry Measurement Systems

Given the increasing application of quantitative MS methods (with stable isotope internal standardization) to clinical samples, aspects of quality and risk management must be considered for the assays to ultimately be fit for diagnostic purposes. These aspects are extensively weighed in Vogeser and Segers recent review article. Addressed therein are pre-implementation strategies, quality assurance tools, validation approaches, assay assessment, and regulatory practices.

 

Abstract

Thanks to highly specific analyte detection and potentially complete compensation for matrix variables based on the principle of stable isotope derivative internal standardisation, mass spectrometry methods allow the development of diagnostic tests of outstanding analytical quality. However, these features per se do not guarantee reliability of tests. A wide range of factors can introduce analytical errors and inaccuracy due to the extreme complexity of the methods involved. Furthermore, it can be expected that the application patterns of MS methods in diagnostic laboratories will change substantially during the coming years - with presumably less specialised laboratories implementing mass spectrometry. Introduction of highly automated test solutions by manufacturers will require some trade-off between operation convenience, sample throughput and analytical performance. Structured and careful quality and risk management is therefore crucial to translate the analytical power of mass spectrometry into actionable and reliable results for individual patients' care and to maintain the degree of reliability that is expected from MS methods in clinical pathology. This reflection review discusses whether particular quality assurance tools have to be applied for MS-based diagnostic tests and whether these tools are different from those applied for optical- and affinity-based standard tests. Both pre-implementation strategies and surveillance of assays with assessment of metadata in routine testing are addressed. The release of the CLSI guideline C62-A in 2014 was a substantial achievement in this context because it addresses a wide spectrum of relevant issues in quality assurance of mass spectrometry-based clinical tests. However, the translation of this best practice document into individual laboratory settings is likely to be heterogeneous. 

Vogeser M, Seger C

Read article






Stable Isotope Newsletters | Cambridge Isotope Laboratories
stable isotope, stable isotope labeled compounds, environmental contaminant standards
CIL has been ready to help with the analytical standards critical to the task of defining and resolving any major environmental contamination problems.